ಈ Publication Issue ನಿಮ್ಮ ಭಾಷೆಯಲ್ಲಿ ಅಸ್ತಿತ್ವದಲ್ಲಿಲ್ಲ, ರಲ್ಲಿ ವೀಕ್ಷಿಸಿ: Français (fr), Español (es), English (en),
ಅಥವಾ Google Translate ಬಳಸಲು:  
By: Charlie Forst
Published: 2002-01-01


Introduction

TN 87 title pictureSeed storage is often a problem in the tropics. However, if seeds can be properly dried, they will remain viable for a longer period of time. The seed drying cabinet described here can help improve the viability of seeds in storage.

Description

The cabinet described in this Technical Note is approximately 32 in (80 cm) wide, 40 in (100 cm) high, and 8 in (20 cm) deep. These dimensions may be varied to suit the material you have to work with. 

The cabinet consists of two chambers (see Diagram 1). The upper chamber contains four sixty-watt electric light bulbs to furnish heat, and a radial or squirrel cage fan to produce air movement throughout the cabinet. The lower chamber is built to accommodate drying trays that have wire mesh bottoms or bins or canisters with perforated sides and that can be stacked one on top of another. Baskets can also be used but should not be woven too tightly. 

The two chambers are separated by a fiberglass filter or other appropriate filter. The fan moves the heated air from the upper chamber into a plenum which encompasses one entire side of the cabinet (see Diagram 1). This plenum is approximately 2 in (5 cm) wide. The height and depth dimensions are the same as those of the cabinet.

The air moves downward and under the plenum wall. It moves under and upwards through a latticed floor, then upwards through the drying trays or other containers, and finally through the filter into the upper chamber to be reheated and recirculated. 

Each electric light bulb contributes heat to the chamber and each is controlled by a separate toggle switch so that the amount of heat produced can be controlled. The fan is controlled by a separate switch. See Table 1 for information about how the amount of wattage used (at different ambient temperatures and relative humidities) impacts the cabinet temperature and relative humidity.

TN 87 diagram 1Diagram 1: Front view of drying cabinet

The cabinet top cover is not fastened to the top chamber. This facilitates filter and bulb changing or fan servicing. Thermometer and humidity gauges are placed in the upper chamber on top of the filter. The upper front panel is attached permanently to the upper cabinet chamber. Do not try to make the top cover or doors hermetically tight. Air leakage (escape) from these areas is necessary for humidity control. Single or double side swinging doors are mounted under the switch panel to protect the integrity of the drying chamber when in operating mode.

Table 1: Temperature and relative humidity observations. Compiled from cold start. Operating figures depend on ambient temperature, relative humidity, and nature of the cabinet load.
Wattage Start Cabinet Temperature (°C) Cabinet Relative Humidity (%) Ambient Temperature (°C) Ambient Relative Humidity (%)
240 28 48 31 72
240 40 20 32 60
240 42 18 32 58
240 42 16 31 56
180 42 15 29 55
120 38 21 31 60
120 39 19 31 62
60 37 19 27 74
60 27 19 25 44
Note: When cabinet temperature and humidity figures can be practically achieved and maintained so that their sums total 46 or less, one may expect viable seed storage for a year or more.

 

Cite this article as:

Forst, C. 2002. Seed Drying Cabinet. ECHO Technical Note no. 87.